howto:stationcoax [2021/07/10 19:11] – [Outside] va7fi | howto:stationcoax [2021/07/10 19:14] – [Inside] va7fi | ||
---|---|---|---|
Line 10: | Line 10: | ||
* The box shown here is 9" | * The box shown here is 9" | ||
* Two pieces of flattened copper pipe are used as bus bars. | * Two pieces of flattened copper pipe are used as bus bars. | ||
- | * The coax from the antennas connect into the [[https:// | + | * The coax from the antennas connect into the [[https:// |
* From there, RG-8X coax is used to go inside the house. | * From there, RG-8X coax is used to go inside the house. | ||
On the grounding side: | On the grounding side: | ||
- | * The antennas up the tree are grounded to a few ground | + | * The antennas up the tree are grounded to a ground |
* Those are bonded to the ground plate that connects to the transition box. | * Those are bonded to the ground plate that connects to the transition box. | ||
* That is also bonded to the utility ground of the house. | * That is also bonded to the utility ground of the house. | ||
Line 21: | Line 21: | ||
===== Inside ===== | ===== Inside ===== | ||
{{ : | {{ : | ||
- | * The RG-8X from the transition box connects to the bottom | + | * The RG-8X from the transition box connects to the back of a patch panel, and the front is labelled with which antenna is connected there. |
* Radios connect to the top of the patch panel, and the patch cords are labelled with the radio. | * Radios connect to the top of the patch panel, and the patch cords are labelled with the radio. | ||
* The patch panel is bonded to the transition box outside, and the radios are connected to the patch panel. | * The patch panel is bonded to the transition box outside, and the radios are connected to the patch panel. |